Nevada Administrative Code
Chapter 445A - Water Controls
PUBLIC WATER SYSTEMS
Certification of Laboratories to Analyze Drinking Water
Section 445A.54268 - Requirements for certification in certain areas

Universal Citation: NV Admin Code 445A.54268

Current through September 16, 2024

1. To be certified to conduct laboratory testing, a laboratory must comply with the requirements set forth in sections 1.8.3, 4.1.1, 5.0, 5.1 and 5.4 to 5.16, inclusive, of the Standards.

2. To be certified in:

(a) Chemistry, a laboratory must comply with the requirements set forth in section 1.8.5 and Appendix D.1 of chapter 5 of the Standards;

(b) Microbiology, a laboratory must comply with the requirements set forth in section 1.8.7 and Appendix D.3 of chapter 5 of the Standards; or

(c) Radiochemistry, a laboratory must comply with the requirements set forth in section 1.8.8 and Appendix D.4 of chapter 5 of the Standards.

3. To be certified pursuant to the program specified in subsection 3 of NAC 445A.54264, a laboratory must comply with the provisions concerning method detection limits, sample containers, holding times, proficiency testing and quality assurance set forth in 40 C.F.R. §§ 141.21(c), 141.21(f), 141.23(k), 141.24(e), 141.24(f)(17), 141.24(f)(20), 141.24(h)(13), 141.24(h)(19), 141.25, 141.30(e), 141.40(g), 141.40(n)(11), 141.40(n)(12), 141.74(a) and 141.89.

4. To be certified for an approved method of testing, a laboratory must comply with the requirements for using that approved method of testing specified in subsection 4 of NAC 445A.54264 and the Standards. If a conflict occurs between a provision specified in that subsection and the Standards concerning an approved method of testing, the Standards apply. If a manufacturer provides instructions for maintaining any equipment used for testing or for ensuring the performance of any test or demonstrating the performance of any system of measurement, the laboratory shall comply with those instructions. If a conflict occurs between a provision of those instructions and a provision specified in subsection 4 of NAC 445A.54264 or the Standards, the provisions specified in that subsection or the Standards apply.

5. If a laboratory intends to use a performance-based measurement system or any other alternative method of testing, the laboratory shall, before the Bureau conducts an inspection of the laboratory pursuant to the provisions of NAC 445A.5428, submit to the Bureau a written statement setting forth the performance-based measurement system or other alternative method of testing it intends to use. The Bureau may approve the performance-based measurement system or alternative method of testing if, as determined by the Bureau:

(a) The system or method is equivalent to or exceeds the approved method of testing for accuracy, precision, completeness and comparability relating to determining compliance with the regulatory concentration levels or system conditions;

(b) An approved method of testing is not available for use by the laboratory to determine the presence of an analyte for which the laboratory requests certification pursuant to the provisions of NAC 445A.542 to 445A.54296, inclusive; or

(c) The laboratory obtains approval for the system or method from the Environmental Protection Agency.

6. To be certified to test for a specific analyte using an approved method of testing, a laboratory must comply with the requirements established by the Bureau for the approved method of testing and the Standards for initial and continuing calibrations of test equipment and demonstrations by analysts of precision, accuracy, sensitivity and low system background for each analyte. If a conflict occurs between the requirements established by the Bureau and the Standards, the Standards apply.

7. As used in this section:

(a) "Holding times" has the meaning ascribed to it in Appendix B of chapter 5 of the Standards.

(b) "Low system background" means an analysis of a method blank that does not yield contamination at a concentration that is greater than the method detection limit.

(c) "Method blank" has the meaning ascribed to it in Appendix B of chapter 5 of the Standards.

(d) "Method detection limit" has the meaning ascribed to it in Appendix B of chapter 5 of the Standards.

(e) "Quality assurance" has the meaning ascribed to it in Appendix B of the Standards.

Added to NAC by Bd. of Health by R203-99, eff. 8-1-2001

NRS 445A.860, 445A.863

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.