1. An accessory structure may be allowed to plumb into an individual sewage disposal system that serves a single-family dwelling if:

(a) The accessory structure is used in conjunction with the single-family dwelling; and

(b) The septic tank has sufficient capacity to accommodate the total number of fixtures in the accessory structure and the single-family dwelling, as determined by the following table:

TYPE OF FIXTURE FIXTURE UNITS
Bathtub 2
Bidet 2
Drinking fountain 1
Floor drain 2
Interceptor:
For items such as grease, oil or solids 3
Laundry tub 2
Machine for washing clothes 2
Sewer connection for a recreational vehicle 6
Shower, single stall 2
Sink:
Bar, private (1 1/2-inch or 38.1 -millimeter minimum waste) 1
Bathroom (single) 1
Bathroom (double) 2
Kitchen, with or without dishwasher (2-inch or 50.8 -millimeter minimum waste) 2
Service 3
Toilet 6
Urinal 2

2. For the purposes of this section, each fixture unit must be rated at 25 gallons.

Added to NAC by Bd. of Health by R100-07, eff. 10-31-2007

NRS 439.200, 444.650

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.