Nevada Administrative Code
Chapter 444 - Sanitation
SEWAGE DISPOSAL
Individual Sewage Disposal Systems
Section 444.7962 - Determination of appropriate percolation test procedure

Universal Citation: NV Admin Code 444.7962
Current through September 16, 2024

In conducting a percolation test, the following flow chart must be used to determine which test procedure to follow:

1) Fill the percolation hole with water to a depth of at least 12 inches over the aggregate. Determine the time needed for the water to seep away completely.
2) Fill the percolation hole with water again to a depth of at least 12 inches over the aggregate. Determine if the water seeps away in 10 minutes or less.
3a) If water is left in the percolation hole after 10 minutes, proceed with the PRESOAKING PROCEDURE, followed by the SLOW PERCOLATION TEST PROCEDURE. 3b) If the water has completely seeped away after 10 minutes, proceed with the FAST PERCOLATION TEST PROCEDURE.

Added to NAC by Bd. of Health by R129-98, eff. 3-25-99

NRS 439.200, 444.650

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.