Construction of Spa
Section 444.450 - Handholds
Universal Citation: NV Admin Code 444.450
Current through September 16, 2024
1. A public spa must be provided with suitable handholds around the perimeter in areas where the spa is more than 3 feet 6 inches (1.07 m) deep, measured from the deepest point of the spa floor to the waterline.
2. Handholds must be spaced no farther apart than 4 feet (1.22 m) and must be provided with a suitable, slip-resistant surface.
3. Handholds may be:
(a) Ledges, radiused flanges, or cantilevered
decks along the immediate top edge of the spa, located not more than 1 foot
(30.50 cm) above the waterline.
(b)
A rope or railing placed not more than 1 foot (30.50 cm) above the waterline,
fastened to the spa wall.
(c)
Ladders, steps and seat ledges.
(d)
A combination of the handholds listed in this section.
4. The overhang for coping or cantilevered decking:
(a) Must not exceed 2 inches (5.08
centimeters) or be less than 1 inch (2.54 centimeters).
(b) Must not exceed 2 1/2 inches (6.4
centimeters) in thickness for a spa for which an operating permit has been
issued before January 16, 1996.
(c)
Must not exceed 3 1/2 inches (8.89 centimeters) in thickness for a spa for
which an operating permit is issued on or after January 16, 1996.
Bd. of Health, Public Spa Reg. Art. 11 §§ 11.4-11.4.4, eff. 11-27-79-NAC A 11-2-88; 1-16-96
NRS 439.200, 444.070
Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.