Section 444.446 - Recessed treads

Universal Citation: NV Admin Code 444.446

Current through September 16, 2024

Recessed treads, when provided, must meet the following specifications:

1. Stepholes must be:

(a) Uniformly spaced, not more than 1 foot (30.48 cm) nor less than 7 inches (17.48 cm) apart at the centerline.

(b) At least 5 inches (12.70 cm) deep and at least 1 foot (30.48 cm) wide.

2. Stephole treads must be sloped to drain into the spa to prevent accumulation of dirt.

3. The vertical distance between the spa coping edge and the uppermost recessed tread must be 1 foot (30.48 cm) or less.

4. Each set of recessed treads must be provided with two handrails which fully serve all treads and risers.

Bd. of Health, Public Spa Reg. Art. 12 §§ 12.5-12.5.5, eff. 11-27-79

NRS 439.200, 444.070

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.