Nevada Administrative Code
Chapter 444 - Sanitation
PUBLIC BATHING PLACES
Miscellaneous Facilities
Section 444.207 - Isolation and flotation tanks

Universal Citation: NV Admin Code 444.207

Current through September 16, 2024

1. The recirculation, filtration and disinfection systems of isolation and flotation tanks must complete no fewer than four turnover cycles between users of the tank.

2. The maximum bathing load in a tank is one person.

3. The solution in the tank must be disinfected by normal chlorination or bromination at 3.0 to 5.0 ppm.

4. Notices must be posted in the vicinity of the tank in the manner and with the information required by NAC 444.530.

5. The maximum temperature of the solution in the tank must not exceed 95°F (35°C).

6. The tank must be designed or ventilated to prevent any hazardous concentration of fumes from toxic disinfectants under all circumstances of operation.

Added to NAC by Bd. of Health, eff. 11-1-88

NRS 439.200, 444.070

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.