Nevada Administrative Code
Chapter 444 - Sanitation
PUBLIC BATHING PLACES
General Standards for Construction
Section 444.152 - System for recirculation
Current through September 16, 2024
1. Except as otherwise provided in NAC 444.198 to 444.1995, inclusive, and 444.202, a recirculation system, consisting of pumps, filters, water conditioning, disinfection equipment and other accessory equipment, must be provided at each public bathing or swimming facility which will recirculate, clarify and disinfect the volume of water used in the facility every 6 hours or less.
2. The patterns of recirculation developed in any pool must be partial flow through the main drain and the remainder through the overflow gutters or skimmers.
3. The recirculation system must include a vacuum gauge located on or immediately before the pump on the suction side of the system and a pressure gauge immediately after the pump on the pressure side of the system.
4. The recirculation system must be operated at all times the facility is open for use and for not less than 3 hours after the facility is closed. If the system is shut down for periodic maintenance and repair, no person who is not an employee of the facility may be allowed into the facility.
5. If time clocks are used to govern the operation of the recirculation system, they must be:
Bd. of Health, Public Bathing Places Reg. Art. 26 §§ 26.1 & 26.2, eff. 5-21-74-NAC A 11-1-88
NRS 439.200, 444.070