Freeboard is required for all storage structures and is a separate requirement from the minimum design storage capacity above. Freeboard is no less than the required vertical separation from the elevation at which liquid will flow out of the facility down to the required minimum storage capacity. Freeboard varies for different types of facilities as follows:

003.01 For earthen structures such as holding ponds whether using an earthen liner or synthetic liner, 1.5 feet;

003.02 For uncovered vertical walled structures such as concrete or steel tanks, twelve inches; and

003.03 For covered vertical wall structures such as underfloor pits, six inches.

Disclaimer: These regulations may not be the most recent version. Nebraska may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.