Rule 24.321.305 - ROOF AREAS

Universal Citation: MT Admin Rules 24.321.305

Current through Register Vol. 6, March 22, 2024

(1) Roof coverings shall have at least a Class B roof assembly or an approved noncombustible roof covering. If the profile of the covering is such that a space is present between the covering and the roof decking, the space at the eave ends shall be fire-stopped to prevent the entry of flames or embers; or have one layer of 72-pound mineral-surfaced, nonperforated cap sheet, complying with ASTM D 3909, and installed over the combustible decking.

(2) When roof valleys are present, valley flashing shall consist of not less than 0.019-inch (26-gauge galvanized sheet) corrosion-resistant metal installed over a minimum three-foot wide underlayment of one layer of 72-pound mineral-surfaced, nonperforated cap sheet, complying with ASTM D 3909, and installed over the entire running length of the valley.

(3) Eaves, soffits, and fascias that are combustible shall be enclosed with solid materials with a minimum thickness of 3/4 inch. Rafter tails shall not be left exposed, unless constructed of heavy timber materials.

(4) If a structure is not located in a designated WUI, the roof assemblies listed in this rule shall comply with the IRC.

50-60-901, MCA; IMP, 76-3-504, MCA;

Disclaimer: These regulations may not be the most recent version. Montana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.