Administrative Rules of Montana
Department 24 - LABOR AND INDUSTRY
Chapter 24.301 - BUILDING CODES
Subchapter 24.301.4 - Electrical Requirements
Rule 24.301.411 - WIRING STANDARDS
Universal Citation: MT Admin Rules 24.301.411
Current through Register Vol. 6, March 22, 2024
(1) The National Electrical Code is amended as follows:
(a) NEC ARTICLE 110.2 (SUPPLEMENTARY). When
requested, complete wiring diagrams shall be provided prior to installation of
conductors and equipment indicating the conductor's and equipment's intended
use.
(b) NEC Article 550.32(A): The
allowable distance for service equipment from the exterior wall of a
manufactured or mobile home is increased from 30 ft (9.14 m) to 50 ft (15.24
m).
(c) NEC Article 550.33(A): Add
the following: It shall be permissible to feed a manufactured (mobile) home
with type SER cable when the service equipment is mounted on the exterior of
the home. Physical protection of the cable is required by enclosing the cable
in an approved raceway where the cable is run on the outside of the home. The
cable is to be properly supported and attached per Article 338 where installed
under the home.
(d) NEC Article
760.1 (SUPPLEMENTARY). Smoke alarms and carbon monoxide alarms shall be
installed in any building or structure as required under the currently adopted
International Building Code or International Residential Code, whichever
applies, regardless of whether or not the building or structure is exempt by
50-60-102,
MCA.
AUTH: 50-60-203, 50-60-603, MCA IMP: 50-60-203, 50-60-603, MCA.
Disclaimer: These regulations may not be the most recent version. Montana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.