Rule 19-7-5.06 - Installation Standards For Used Factory-Built Homes
Section 19-7-5.06.8 - Pier Spacing and Placement
Section 19-7-5.06.8.3 - Placement of Piers Under Concentrated Loads
Universal Citation: MS Code of Rules 19-7-5.06.8.3
Current through March 31, 2025
Piers shall be placed under other concentrated loads such as porch posts, bay window overhangs, and masonry faced fireplaces or floor overhangs. Factory-Built Homes that exceed 16 ft, per floor, in width shall have perimeter piers under the sidewalls every 6 ft. and at each corner. The data plate of the Factory-Built home must be reviewed by the installer/transporter to determine if additional perimeter pier installations are required.
Miss. Code Ann. §§ 75-49-1, et seq.; 75-49-11 (Supp. 2015).
Disclaimer: These regulations may not be the most recent version. Mississippi may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.