Mississippi Administrative Code
Title 15 - Mississippi Department of Health
Part 21 - Division of Radiological Health
Subpart 78 - Radiological Health
Chapter 1 - REGULATIONS FOR CONTROL OF RADIATION IN MISSISSIPPI
Subchapter 9 - Radiation Safety Requirements for Particle Accelerators
Rule 15-21-78-1.9.9 - Warning Devices
Current through September 24, 2024
1. Each location designated as high radiation area, and each entrance to such location, shall be equipped with easily observable warning lights that operate when, and only when, radiation is being produced.
2. Except in facilities designed for human exposure, each high radiation area shall have an audible warning device which shall be activated for 15 seconds prior to the possible creation of such high radiation area. Such warning device shall be clearly discernible in all high radiation areas.
3. Barriers, temporary or otherwise, and pathways leading to high radiation areas shall be posted in accordance with 1.4.30 of these regulations.
Miss. Code Ann. § 45-14-11