Mississippi Administrative Code
Title 12 - Finance and Administration
Part 10 - Office of State Property Insurance
Sec2 12-10-300 - PROVISIONS FOR FLOOD HAZARD REDUCTION
Section 12-10-300.2 - Specific Standards
Current through September 24, 2024
In all areas of Special Flood Hazards where base flood elevation data has been provided, the following provisions are required:
(1) Residential Construction - New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to one foot (1'), above the base flood elevation. A registered (in Mississippi) land surveyor shall certify that the standards of the subsection are satisfied. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the impeded movements of flood waters shall be provided in accordance with standards Elevated Buildings, Section 300, Paragraph 300.2(3).
(2) Non-Residential Construction - New construction or substantial improvement of any commercial, industrial, or non-residential structure shall have the lowest floor, including basement, elevated no lower than one foot (1') above the level of the base flood elevation. Structures located in all A zones may be flood-proofed in lieu of being elevated provided that all areas of the structure below the required elevation are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered (in Mississippi) professional engineer or architect shall develop and /or review structural design, specifications, and plans for the construction and shall certify that design and method of construction are in accordance with accepted standards of practice.
(3) Elevated Building.
New construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of flood waters to the automatically equalize hydrostatic flood forces on exterior walls.
(4) Floodways - Located within areas of special flood hazard are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and has erosion potential, all development with a floodway is permitted (except manufactured homes which are specifically prohibited) provided the development does not result in any increase in the water surface elevation of the base flood, the development is designed to withstand the velocity waters associated waters associated with the base flood waters, and the development would present no significant obstruction to the flow of the base flood waters, and would not create hazards to public health and safety. For purposes of meeting the requirements of "no increase in the water surface elevation of the base flood", the following methods shall be acceptable in order of preference:
(5) Manufactured Homes - All manufactured homes (mobile homes shall be installed using methods and practices which minimize flood damage. The placement of manufactured homes (mobile homes) in V Zones is prohibited. For the purpose of this requirement, the following provisions shall apply:
(6) Access (Ingress-Egress) - New development proposals will be designed, to the maximum extent practicable, so residential building sites, walkways, driveways, and roadways are located on land with a natural grade with elevation not less than the base flood elevation and wit dry land access.
(7) Compensatory Storage Required for Fill - Fill within the special flood hazard area shall result in no net loss of natural floodplain storage, or increase in water surface elevations during the base flood. The volume of the loss of floodwater storage due to filling in the special flood hazard area shall be offset by providing an equal volume of flood storage by excavation or other compensatory measures at or adjacent to the development site.
(8) Critical Development - Critical facilities and developments are prohibited in the 1% flood hazard areas. Where critical developments are located adjacent to 1%-chance flood areas, the flood protection elevation shall be two feet above the 0.2% flood elevation and that elevation shall be used as the basis for the Access (Ingress-Egress) provisions.
(9) Fill - The following standards apply to all fill activities in special flood hazard areas:
(10) ASCE 24 Flood Resistant Design and Construction - The American Society of Civil Engineers (ASCE) 24-14 is a referenced standard in the 2015 International Building Code® (IBC) and the 2015 International Residential Code® (IRC). Building and structures within the scope of the IBC proposed to be constructed in flood hazard areas must be designed in accordance with ASCE 24-14. The IRC requires dwellings in floodways to be designed in accordance with ASCE 24-14 and includes an alternative that allows communities to require homes in any flood zone to be designed in accordance with ASCE 24-15. Highlights of ASCE 24-14 that complement the NFIP minimum requirements include: Building Performance; Flood-Damage Resistant Materials; Utilities and Service Equipment and Siting Considerations.
(11) Future Conditions Flood Hazard Area - Require that all map revisions and watershed studies include analyses based on future conditions associated with anticipated watershed growth and land-use and land-cover changes. These future condition analyses shall be included on community floodplain maps and will serve as the basis for this regulation.
(12) Storage of Materials - Storage of material or equipment not otherwise prohibited shall be firmly anchored to prevent flotation.
(13) Setbacks - Setbacks in riverine floodplains:
Setbacks adjacent to blue-line tributaries:
Setbacks in coastal floodplains
(14) Stormwater Regulations - All development proposals which (involve disturbing more than 10,000 square feet of land - removed) disturb one acre of land or more shall include a storm water management plan which is designed to limit peak runoff from the site to predevelopment levels for the 1, 10, and 100 year rainfall event. These plans shall be designed to limit adverse impacts to downstream channels and floodplains.
(15) Elevation of All Additions - All new horizontal additions must have the lowest floor and all HVAC elevated to one foot above the base flood elevation. Non-residential additions may be dry flood proofed to one foot above the base flood elevation.
(16) Sinkholes - A sinkhole, the immediate sinkhole drainage area, a sinkhole cluster area, or portions of such items shall be shown on any development or preliminary subdivision plan for land where they exist. Sinkhole-related nonbuildable areas and restricted fill areas shall be shown on final subdivision plans and development plans. No buildings, parking areas, or other structures shall be permitted within the sinkhole related, non-buildable area. Development may occur in the immediate sinkhole drainage area if the developer provides alternative surface drainage away from the sinkhole, while keeping the water in the same surface drainage basin, and provided further that the water shall not go into another sinkhole drainage area off the petitioner's property, nor into another stream of known flooding problems. The immediate sinkhole drainage system area (or portion thereof) which cannot be provided with an alternative drainage system can be deleted from the development area and can be used to meet the normal open space requirements.