Current through September 24, 2024

For PAH analysis collect one water sample (1 liter) from each sampling point.

1. Sampling containers should be pre-labeled before any sample collection begins.

2. Transfer the sample from the bailer to a one liter widemouth glass sampling container with a Teflon liner. Completely fill container to the top.

3. Immediately store the samples on ice and ship to the laboratory within 24 hours of collection.

BTEX and PAH Sample Handling Requirements for Soil/Groundwater Samples
Parameter Media Container
BTEX (Gasoline) Soil One 4-oz (120-ml) amber glass with Teflon liner
PAH (Diesel, Oil, etc.) Soil One 8-oz (250-ml) amber widemouth glass with Teflon liner
BTEX (Gasoline) Water Three 40-ml amber vials with septum caps
PAH (Diesel, Oil, etc.) Water One 1 liter widemouth glass with Teflon liner

Disclaimer: These regulations may not be the most recent version. Mississippi may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.