7081.0260 - DOSING OF EFFLUENT.

Universal Citation: MN Rules 7081.0260
7081.0260 DOSING OF EFFLUENT.

A. Dosing of effluent into a soil treatment and dispersal system must comply with part 7080.2100 except as modified in this part.

B. The dosing system must include an alternating two-pump system and have a minimum total capacity of 50 percent of the design flow.

C. The pump discharge capacity must be based on the perforation's discharge, with a minimum average head of two feet for 1/4 inch and 3/16 inch perforations and five feet for 1/8 inch perforations.

Statutory Authority:

MS s 115.03; 115.55

History:

32 SR 1400

Published Electronically:

March 11, 2011

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.