7080 - INDIVIDUAL SUBSURFACE SEWAGE TREATMENT SYSTEMS
7080.1940 - MULTIPLE SEPTIC TANKS.

Universal Citation: MN Rules 7080.1940
7080.1940 MULTIPLE SEPTIC TANKS.

A. If more than one septic tank is used to obtain the required liquid capacity as determined in part 7080.1930, septic tanks must be connected in series or employ multiple collection systems.

B. When tanks are connected in series, each tank or compartment must contain at least 25 percent of the required total liquid capacity.

Statutory Authority:

MS s 115.03; 115.55

History:

32 SR 1347; 35 SR 1353

Published Electronically:

October 10, 2013

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.