Minnesota Administrative Rules
Plumbing Board
4714 - PLUMBING CODE
4714.0421 - FIXTURES AND FIXTURE FITTINGS FOR PERSONS WITH DISABILITIES.

Universal Citation: MN Rules 4714.0421
4714.0421 FIXTURES AND FIXTURE FITTINGS FOR PERSONS WITH DISABILITIES.

UPC section 421.2 is amended to read as follows:

421.2 Limitation of Hot Water Temperature for Public Lavatories. Hot water delivered from public-use lavatories shall be limited to a maximum temperature of 110º F (43º C) by a device that is in accordance with ASSE 1070 or CSA B125.3. The water heater thermostat shall not be considered a control for meeting this provision.

Statutory Authority:

MS s 326B.43; 326B.435

History:

40 SR 71

Published Electronically:

January 25, 2016

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.