Minnesota Administrative Rules
Agency 167 - Pollution Control Agency
Chapter 7080 - INDIVIDUAL SUBSURFACE SEWAGE TREATMENT SYSTEMS
Part 7080.1940 - MULTIPLE SEPTIC TANKS
Universal Citation: MN Rules 7080.1940
Current through Register Vol. 49, No. 13, September 23, 2024
A. If more than one septic tank is used to obtain the required liquid capacity as determined in part 7080.1930, septic tanks must be connected in series or employ multiple collection systems.
B. When tanks are connected in series, each tank or compartment must contain at least 25 percent of the required total liquid capacity.
Statutory Authority: MS s 115.03; 115.55
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.