A preliminary evaluation of a proposed site for an ISTS consists of determining the following items:
A. design flow, anticipated effluent concentrations of biochemical oxygen demand, total suspended solids, and oil and grease, and anticipated presence of nondomestic waste from the dwelling, dwellings, or other establishments;
B. proposed or existing:
C. easements on the lot;
D. the ordinary high water level of public waters, if adjacent to the lot;
E. floodplain designation and flooding elevation from published data or data that is acceptable to and approved by the local unit of government or the Department of Natural Resources, if applicable;
F. property lines;
G. all required setbacks from the system;
H. the soil characteristics at the proposed soil treatment and dispersal areas as obtained from the soil survey report, if available, including the soil map, map units, landscape position, parent material, flooding potential, slope range, periodically saturated soil level, depth to bedrock, texture, color, depth to redoximorphic features, and structure and consistence of soil horizons;
I. a township, range, and section number and other unique property identifiers as required by local government and lot dimensions;
J. names of property owners; and
K. the inner wellhead management zone or wellhead protection area of a public water supply, if applicable.
Statutory Authority: MS s 115.03; 115.55