Minnesota Administrative Rules
Agency 167 - Pollution Control Agency
Chapter 7041 - SEWAGE SLUDGE MANAGEMENT
Part 7041.3000 - CALCULATION OF AVAILABLE AND CARRY-OVER NITROGEN

Universal Citation: MN Rules 7041.3000

Current through Register Vol. 48, No. 39, March 25, 2024

Subpart 1. Available nitrogen.

The formulas in this subpart shall be used for the calculation of available nitrogen for the cropping year sewage sludge is applied to the land unless it has been demonstrated to the satisfaction of the commissioner with data from laboratory and/or field tests that another calculation based on sewage sludge or site-specific mineralization rates is more appropriate.

POUNDS OF AVAILABLE NITROGEN PER TON

OF SEWAGE SLUDGE SOLIDS

Type of Stabilization Application Method Formula
Digested
Anaerobic Surface (% organic-N x 4) + (%NH3-N x 10)
Anaerobic Incorporated1 or injected (% organic-N x 4) + (%NH3-N x 20)
Aerobic Surface (% organic-N x 6) + (%NH3-N x 10)
Aerobic Incorporated1 or injected (% organic-N x 6) + (%NH3-N x 20)
Stabilized primary and waste activated Surface Incorporated1 or injected (% organic-N x 8) + (%NH3-N x 10) (% organic-N x 8) + (%NH3-N x 20)
Composted Surface (% organic-N x 2) + (%NH3-N x 10)
Incorporated1 (% organic-N x 2) + (%NH3-N x 20)

1Incorporated within 48 hours

Subp. 2. First year carry-over nitrogen.

First year carry-over nitrogen from the initial application of sewage sludge shall be calculated using the formulas in this subpart.

FIRST YEAR CARRY-OVER NITROGEN FROM INITIAL

SEWAGE SLUDGE APPLICATION

Type of Stabilization Pounds per Acre
Anaerobically digested (% organic-N) x (1.6) x (tons per acre applied)
Aerobically digested (% organic-N) x (2.1) x (tons per acre applied)
Stabilized primary and waste activated (% organic-N) x (2.4) x (tons per acre applied)
Composted (% organic-N) x (0.9) x (tons per acre applied)

Subp. 3. Second year carry-over nitrogen.

Second year carry-over nitrogen from the initial application of sewage sludge must be calculated for aerobically digested and stabilized primary and waste activated sewage sludge if the initial application provided greater than or equal to 100 pounds of available nitrogen per acre. The following formula shall be used:

Second year carry-over nitrogen = (% organic-N) x (1.0) x (tons/acre applied).

Statutory Authority: MS s 116.07

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.