Minnesota Administrative Rules
Agency 167 - Pollution Control Agency
Chapter 7011 - STANDARDS FOR STATIONARY SOURCES
INDUSTRIAL PROCESS EQUIPMENT
Part 7011.0735 - TABLE 2
Universal Citation: MN Rules 7011.0735
Current through Register Vol. 49, No. 13, September 23, 2024
Source Gas Volume, DSCFMa |
Concentration GR/DSCFb |
7,000 or less |
0.100 |
8,000 |
0.096 |
9,000 |
0.092 |
10,000 |
0.089 |
20,000 |
0.071 |
30,000 |
0.062 |
40,000 |
0.057 |
50,000 |
0.053 |
60,000 |
0.050 |
80,000 |
0.045 |
100,000 |
0.042 |
120,000 |
0.040 |
140,000 |
0.038 |
160,000 |
0.036 |
180,000 |
0.035 |
200,000 |
0.034 |
300,000 |
0.030 |
400,000 |
0.027 |
500,000 |
0.025 |
600,000 |
0.024 |
800,000 |
0.021 |
1,000,000 or more |
0.020 |
Interpolation of the data in this part for airflow rates between 7,000 dscfm and 1,000,000 dscfm must use the equation:
c = 1.7627 x FRcorrected-0.3241
where:
c = concentration limit in gr/dscf
FRcorrected = gas volume in dscfm
aDry standard cubic feet per minute
bGrains per dry standard cubic foot.
Statutory Authority: MS s 116.07
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.