Subpart 1. In general.
Performance tests shall be conducted according to the requirements of this part and parts 7017.2001 to 7017.2060.
Subp. 2. Sampling time for Method 5.
For Method 5, the sampling time for each run shall be at least 60 minutes and the sampling rate shall be at least 0.015 dscm/min (0.53 dscf/min), except that shorter sampling times, when necessitated by process variables or other factors, may be approved by the agency.
Subp. 3. Dry sludge charging rate.
Dry sludge charging rate shall be determined as follows:
RdvSv | ||
Sd = (60 x 10-3) | _____ | (Metric Units) |
T |
or
RdvSv | ||
Sd = (8.021) | _____ | (English Units) |
T |
where:
Sd = average dry sludge charging rate during the run, kg/hr (English units: lb/hr);
Rdv = average quantity of dry sludge per unit volume of sludge charged to the incinerator, mg/1 (English units: lb/ft3);
Sv = sludge charged to the incinerator during the run, m3 (English units: gal);
T = duration of run, min (English units: min);
60x10-3 = metric units conversion factor, 1-kg-min/m3-mg-hr;
8.021 = English units conversion factor, ft3-min/gal-hr.
RdmSm | ||
Sd = (60) | _____ | (Metric or English Units) |
T |
where:
Sd = average dry sludge charging rate during the run, kg/hr (English units: lb/hr);
Rdm = average ratio of quantity of dry sludge to quantity of sludge charged to the incinerator, mg/mg (English units: lb/lb);
Sm = sludge charged during the run, kg (English units: lb);
T = duration of run, min (metric or English units);
60 = conversion factor, min/hr (metric or English units).
Subp. 4. Particulate emission rate.
Parti culate emission rate shall be determined by:
Caw = CsQ3 (metric or English units) where:
Caw = Particulate matter mass emissions, mg/hr (English units: lb/hr).
Cs = Particulate matter concentration, mg/m3 (English units: lb/dscf).
Qs = Volumetric stack gas flow rate, dscm/hr (English units: dscf/hr). Qs and cs shall be determined using methods 2 and 5, respectively.
Subp. 5. Compliance with standards.
Compliance with part 7011.1310 shall be determined as follows:
Caw | ||
Cds = (10-3) | _____ | (Metric Units) |
Sd |
or
Caw | ||
Cds = (2000) | _____ | (English Units) |
Sd |
where:
Cds = particulate emission discharge, g/kg dry sludge (English units: lb/ton dry sludge).
10-3 = Metric conversion factor, g/mg.
2,000 = English conversion factor, lb/ton.
Statutory Authority: MS s 116.07