Minnesota Administrative Rules
Agency 167 - Pollution Control Agency
Chapter 7011 - STANDARDS FOR STATIONARY SOURCES
HOT MIX ASPHALT PLANTS
Part 7011.0911 - MAINTENANCE OF DRYER BURNER
Universal Citation: MN Rules 7011.0911
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. Annual tuning of dryer burner.
The owner or operator of a hot mix asphalt plant must tune the dryer burner for maximum combustion efficiency once each calendar year.
Subp. 2. Daily check of dryer burner.
The owner or operator of a hot mix asphalt plant must do the following while producing hot mix asphalt each day except when burning natural gas or propane:
A. read the fuel
pressure gauge on the dryer burner; and
B. check for a negative draft at the dryer
burner inlet.
Subp. 3. Records kept on dryer burner.
The owner or operator of a hot mix asphalt plant must maintain a record of:
A. the dates of
the annual tuning of the dryer burner;
B. the daily reading from the fuel pressure
gauge on the dryer burner except when burning natural gas or propane;
C. whether there was a negative draft at the
dryer burner inlet each day except when burning natural gas or propane;
and
D. any corrective actions taken
as a result of the daily checks required by subpart
2.
Statutory Authority: MS s 116.07
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.