Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 7511 - FIRE CODE
Part 7511.1015 - SECTION 1015, GUARDS
Universal Citation: MN Rules 7511.1015
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. IFC section 1015.2 Where required.
IFC section 1015.2 is amended by adding item 8 to the exception as follows:
8. On bleachers 55 inches
or less in height, in accordance with the Minnesota Bleacher Safety Act,
Minnesota Statutes, section
326B.112.
Subp. 2. IFC section 1015.3 Height.
IFC section 1015.3 is amended by modifying exception 4 to read as follows:
4. The guard height in
assembly seating areas shall be in accordance with section 1029.17 and the
Minnesota Bleacher Safety Act, Minnesota Statutes, section
326B.112.
Subp. 2a. IFC section 1015.6 Mechanical equipment, systems, and devices.
IFC section 1015.6 is amended to read as follows:
1015.6
Mechanical equipment, systems,
and devices. Guards shall be designed and installed in accordance with
the Minnesota Mechanical Code.
Subp. 3. IFC section 1015.8.
IFC section 1015.8 is amended to read:
1015.8
Window openings. In
occupancy groups R-1, R-2, R-3, one- and two-family, multiple-family dwellings,
and townhouses, where the lowest part of the opening of an operable window is
located more than 72 inches (1,829 mm) above the finished grade or other
surface below, the lowest part of the window opening shall be at a height not
less than 36 inches (914 mm) above the finished floor surface of the room in
which the window is located. Operable sections of windows shall not permit
openings that allow passage of a 4 -inch-diameter (102 mm) sphere where such
openings are located within 36 inches (914 mm) of the finished floor.
Exceptions:
1. Operable windows where the lowest part of
the opening is located more than 75 feet (22,860 mm) above the finished grade
or other surface below and that are provided with window fall-prevention
devices that comply with ASTM F 2006.
2. Windows whose openings will not allow a
4-inch-diameter (102 mm) sphere to pass through the opening when the window is
in its largest opened position.
3.
Openings that are provided with window fall-prevention devices that comply with
ASTM F 2090.
4. Windows that are
provided with window opening control devices that comply with section
1015.8.1.
5. Replacement windows
for occupancy groups R-1, R-2, R-3, one- and two-family, multifamily dwellings,
and townhouses located on or below the third story above grade plane.
(Subsection 1015.8.1 remains unchanged.)
Statutory Authority: MS s 299F.011
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.