IFC Section 1014.4 and all subsections are deleted and replaced with the following:
1014.4 Aisles and aisle accessways. Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles and aisle accessways shall be provided from all occupied portions of the exit access. Aisles and aisle accessways serving assembly areas, other than seating at tables, shall comply with Section 1024. Aisles and aisle accessways serving reviewing stands, grandstands and bleachers shall comply with Section 1024.
The required width of aisles and aisle accessways shall be unobstructed.
Exception: Doors, when fully opened, and handrails shall not reduce the required width by more than 7 inches (178 mm). Doors in any position shall not reduce the required width by more than one-half. Other nonstructural projections such as trim and similar decorative features are permitted to project into the required width 1.5 inches (38 mm) from each side.
Exception: Portions of an aisle accessway having a length not exceeding 6 feet and used by a total of not more than four persons.
Exception: Aisles serving less than 50 people need not exceed 28 inches (711 mm) in width.