Subpart 1. IFC section 1011.14.
IFC section 1011.14 is amended to read:
1011.14
Alternating tread
devices. Alternating tread devices are limited to an element of a means
of egress in buildings of Groups F, H, and S from a mezzanine not more than 250
square feet (23 m2) in area and which serves not
more than five occupants; and in buildings of Groups I-3 from a guard tower,
observation station, or control room not more than 250 square feet (23
m2) in area and for access to unoccupied roofs.
Access to mechanical equipment or appliances on a roof shall be in accordance
with IBC Section 1208.3.1 and the Minnesota Mechanical Code.
(IFC sections 1011.14.1, 1011.14.2, and the exception still apply.)
Subp. 2. IFC section 1011.15.
IFC section 1011.15 and all subsections are deleted in their entirety and replaced with the following:
1011.15
Ships ladders. Ships
ladders constructed as required for permanent stairs in accordance with the
Minnesota Mechanical Code, shall be permitted to be used as a means of egress
component at the following locations:
1.
Ships ladders are permitted to be used in Group I-3 occupancies for means of
egress at control rooms or elevated facility observation stations not more than
250 square feet (23 m2) in floor area.
2. Ships ladders are permitted to be used as
a component for means of egress at recessed or elevated floors or platforms
when the area served has an occupant load of five or fewer, and the space meets
all of the following criteria:
2.1 access to
the area served is limited to building facilities staff, maintenance staff,
employees, or other authorized personnel;
2.2 required access to the area served is
limited and periodic;
2.3 the area
served is used for building maintenance service functions, or for equipment
access or monitoring;
2.4 the area
served is not required to have a second means of egress by other provisions of
this code; and
2.5 the area served
is not classified as a Group H occupancy.
3. Ships ladders are permitted to be used for
access to unoccupied spaces in accordance with the Minnesota Mechanical
Code.
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.