Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 1346 - MINNESOTA MECHANICAL AND FUEL GAS CODES
Chapter 8 - INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT
Part 1346.6010 - IMC APPENDIX C, TABLE C-1
Universal Citation: MN Rules 1346.6010
Current through Register Vol. 49, No. 13, September 23, 2024
IMC Appendix C, Table C-1
Recommended Capacities for Domestic Kitchen Exhaust Hoods
Hood Size | Equipment with Grills or Deep Fryers (Number of Exposed Sides) | Ranges and Ovens (Number of Exposed Sides) | ||
Area (Sq. Ft.) | Four (CFM) | Three (CFM) | Four (CFM) | Three (CFM) |
Up to 4 | Up to 400 | Up to 300 | Up to 300 | Up to 200 |
4 | 400 | 300 | 300 | 200 |
4.5 | 450 | 338 | 338 | 225 |
5 | 500 | 375 | 375 | 250 |
5.5 | 550 | 413 | 413 | 275 |
6 | 600 | 450 | 450 | 300 |
6.5 | 650 | 488 | 488 | 325 |
7 | 700 | 525 | 525 | 350 |
7.5 | 750 | 563 | 563 | 375 |
8 | 800 | 600 | 600 | 400 |
8.5 | 850 | 638 | 638 | 425 |
9 | 900 | 675 | 675 | 450 |
9.5 | 950 | 713 | 713 | 475 |
10 | 1,000 | 750 | 750 | 500 |
10.5 | 1,050 | 788 | 788 | 525 |
11 | 1,100 | 825 | 825 | 550 |
11.5 | 1,150 | 863 | 863 | 575 |
12 | 1,200 | 900 | 900 | 600 |
12.5 | 1,250 | 938 | 938 | 625 |
13 | 1,300 | 975 | 975 | 650 |
13.5 | 1,350 | 1,013 | 1,013 | 675 |
14 | 1,400 | 1,050 | 1,050 | 700 |
14.5 | 1,450 | 1,088 | 1,088 | 725 |
15 | 1,500 | 1,125 | 1,125 | 750 |
15.5 | 1,550 | 1,163 | 1,163 | 775 |
16 | 1,600 | 1,200 | 1,200 | 800 |
Statutory Authority: MS s 326B.101; 326B.106; 326B.13
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.