Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 1341 - ACCESSIBILITY FOR BUILDINGS AND FACILITIES
Part 1341.0408 - A117.1 SECTION 408, LIMITED-USE/LIMITED-APPLICATION ELEVATORS
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. A117.1 Section 408.1, General.
A117.1 Section 408.1 is amended to read as follows:
Exception: When approved by the administrative authority, attendant or key operation shall be permitted when all occupants have controlled or restricted access to the space served by the elevator.
Subp. 2. A117.1 Section 408.3.3, Door location and width.
A117.1 Section 408.3.3 is amended to read as follows:
Exception: Car doors that provide a clear opening width of 36 inches (915 mm) minimum shall be permitted to be located on adjacent sides of cars that provide a clear floor area of 51 inches (1295 mm) in width and 51 inches (1295 mm) in depth.
Subp. 3. A117.1 Section 408.4.1, Inside dimensions of elevator cars.
A117.1 Section 408.4.1 is amended to read as follows:
Exception: For installations in existing buildings, elevator cars that provide a clear floor area of 15 square feet (1.35 m2) minimum, and provide a clear inside dimension of 36 inches (915 mm) minimum in width and 54 inches (1370 mm) minimum in depth, shall be permitted. This exception shall not apply to cars with doors on adjacent sides.
Subp. 4. A117.1 Section 408.4.3, Platform and hoistway clearance.
A117.1 Section 408.4.3 is amended to read as follows:
Statutory Authority: MS s 16B.37; 16B.59 to 16B.76; 326B.101 to 326B.194