Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 1311 - REHABILITATION OF EXISTING BUILDINGS
Part 1311.0503 - SECTION 503, ALTERATIONS
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. Section 503 General.
IEBC section 503.1, the exceptions, are amended to read as follows:
Exceptions:
Subp. 2. Section 503 Existing structural elements carrying gravity load.
IEBC section 503.3 is amended to read as follows:
Subp. 2a. Section 503.4 Existing structural elements carrying gravity load.
The exception to IEBC section 503.4 is amended to read as follows:
Exception: Any existing lateral load-carrying structural element for which an alteration causes an increase in demand-capacity ratio to no more than 110 percent shall be permitted to remain unaltered. For purposes of calculating demand-capacity ratios, the demand shall consider applicable load combinations with design lateral loads or forces in accordance with IBC section 1609. For purposes of this exception, comparisons of demand-capacity ratios and calculation of design lateral loads, forces, and capacities shall account for the cumulative effects of additions and alterations since original construction.
Subp. 3. [Repealed, ]
Subp. 4. [Repealed, ]
Subp. 5. [Repealed, ]
Subp. 6. [Repealed, ]
Subp. 7. [Repealed, ]
Subp. 8. Section 503.14 Smoke Alarms.
IEBC section 503.14 is amended to read as follows:
Subp. 9. Section 503.15 Carbon monoxide alarms.
IEBC section 503.15 is amended to read as follows:
Carbon monoxide alarms shall be provided to protect sleeping units and dwelling units in Group 1-1,1-2,1-4, and R occupancies in accordance with IBC section 915.