Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 1305 - ADOPTION OF INTERNATIONAL BUILDING CODE
Part 1305.3002 - SECTION 3002, HOISTWAY ENCLOSURES
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. IBC section 3002.3.
IBC section 3002.3 is amended as follows:
(The exceptions remain unchanged.)
Subp. 2. IBC section 3002.4.
IBC section 3002.4 is amended to read as follows:
Exception: When approved by the authority having jurisdiction, in passenger elevators to be installed in existing buildings where existing hoistway configuration or technical infeasibility prohibits strict compliance with the minimum inside car size, the minimum inside car area may be reduced to not less than 48 inches by 48 inches.
Subp. 3. IBC section 3002.6.
IBC section 3002.6 is amended to read as follows:
Subp. 4. IBC section 3002.9.
IBC section 3002.9 is amended to read as follows:
(The exception is deleted.)