Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 1305 - ADOPTION OF INTERNATIONAL BUILDING CODE
Part 1305.1009 - SECTION 1009, ACCESSIBLE MEANS OF EGRESS
Universal Citation: MN Rules 1305.1009
Current through Register Vol. 49, No. 13, September 23, 2024
IBC section 1009.1 is amended by adding a new exception to read as follows:
3. Accessible means of egress is not required for alterations to existing buildings.
Subpart 1.
IBC section 1009.13.
IBC section 1009.13 is amended to read as follows:
1009.13
Alternating tread
devices. Alternating tread devices are limited to an element of a means
of egress in buildings of Groups F, H, and S from a mezzanine not more than 250
square feet (23 m2) in area and which serves not
more than five occupants; in buildings of Group I-3 from a guard tower,
observation station, or control room not more than 250 square feet (23
m2) in area and for access to unoccupied roofs.
Access to mechanical equipment or appliances on a roof shall be in accordance
with section 1209.3.1 and the Minnesota Mechanical Code.
(IBC sections 1009.13.1, 1009.13.2, and the exception still apply.)
Subp. 2.
IBC section
1009.14.
IBC section 1009.14 is amended to read as follows:
1009.14
Ships
ladders. Ships ladders constructed as required for permanent stairs in
accordance with Minnesota Rules, part
1305.1209, shall be permitted to
be used as a means of egress component at the following locations:
1. Ships ladders are permitted to be used in
Group I-3 occupancies for means of egress at control rooms or elevated facility
observation stations not more than 250 square feet (23
m2) in floor area.
2. Ships ladders are permitted to be used as
a component for means of egress at recessed or elevated floors or platforms
when the area served has an occupant load of five or less and the space meets
all of the following criteria:
(a) access to
the area served is limited to building facilities staff, maintenance staff,
employees, or other authorized personnel;
(b) required access to the area served is
limited and periodic;
(c) the area
served is used for building maintenance service functions, or for equipment
access or monitoring;
(d) the area
served is not required to have a second means of egress by other provisions of
this code; and
(e) the area served
is not classified as a Group H occupancy.
3. Ships ladders are permitted to be used for
access to unoccupied spaces in accordance with Minnesota Rules, part
1305.1209.
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.