Minnesota Administrative Rules
Agency 151 - Labor and Industry Department
Chapter 1303 - MINNESOTA PROVISIONS OF STATE BUILDING CODE
Part 1303.2320 - WINDOW FALL PREVENTION REQUIRED
Current through Register Vol. 49, No. 13, September 23, 2024
Windows that are required to comply with part 1303.2310 must be equipped with window fall prevention screens, guards, or other devices that comply with ASTM F 2006 or ASTM F 2090.
Exceptions:
1. Fixed, nonoperable windows.
2. Windows located in basements.
3. Windows located below the first story above grade plane.
4. Windows in which the opening of a window in any position does not permit a four-inch diameter sphere to pass through the opening.
5. Windows in which the bottom of the sill is more than 24 inches (610 mm) above the finished floor.
Statutory Authority: MS s 326B.02; 326B.101; 326B.106; 326B.13