Minnesota Administrative Rules
Agency 144 - Health Department
Chapter 4731 - RADIATION SAFETY
SPECIFIC DOMESTIC LICENSING OF RADIOACTIVE MATERIAL
Part 4731.3380 - SPECIFIC LICENSE; ICE DETECTION DEVICES; MANUFACTURE OR INITIAL TRANSFER
Universal Citation: MN Rules 4731.3380
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. Approval criteria.
An application for a specific license to manufacture or initially transfer ice detection devices containing strontium-90 for distribution to persons generally licensed under part 4731.3240 shall be approved if:
A. the applicant
satisfies the general requirements of part 4731.3070;
B. the applicant submits sufficient
information regarding each type of device pertinent to evaluation of the
potential radiation exposure, including:
(1)
chemical and physical form and maximum quantity of strontium-90 in the
device;
(2) details of construction
and design of the source of radiation and its shielding;
(3) radiation profile of a prototype
device;
(4) procedures for and
results of prototype testing of devices to demonstrate that the strontium-90
contained in each device will not be released or be removed from the device
under the most severe conditions likely to be encountered in normal handling
and use;
(5) details of quality
control procedures to be followed in manufacture of the device;
(6) description of labeling to be affixed to
the device;
(7) instructions for
handling and installation of the device; and
(8) any additional information, including
experimental studies and tests, required by the commissioner to facilitate a
determination of the safety of the device;
C. each device will contain no more than 50
microcuries of strontium-90 in an insoluble form;
D. each device will bear durable, legible
labeling that includes:
(1) the radiation
caution symbol prescribed by part 4731.2300;
(2) a statement that the device contains
strontium-90 and the quantity thereof;
(3) instructions for disposal;
(4) a statement that the device may be
possessed pursuant to a general license;
(5) a statement that the manufacturer or
civil authorities should be notified if the device is found;
(6) a statement that removal of the labeling
is prohibited; and
(7) a statement
that disassembly and repair of the device may be performed only by a person
holding a specific license to manufacture or service such devices;
and
E. the commissioner
determines that:
(1) the method of
incorporation and binding of the strontium-90 in the device is such that the
strontium-90 will not be released from the device under the most severe
conditions that are likely to be encountered in normal use and handling of the
device;
(2) the strontium-90 is
incorporated or enclosed so as to preclude direct physical contact by any
individual with it and is shielded so that no individual will receive a
radiation exposure to a major portion of the individual's body in excess of 0.5
rem in a year under ordinary circumstances of use;
(3) the device is so designed that it cannot
be easily disassembled;
(4)
prototypes of the device have been subjected to and have satisfactorily passed
the tests under item F; and
(5)
quality control procedures have been established to satisfy the requirements of
subpart 2;
F. the
applicant subjects at least five prototypes of the device to tests as follows:
(1) the devices are subjected to tests that
adequately take into account the individual, aggregate, and cumulative effects
of environmental conditions expected in service that could adversely affect the
effective containment of strontium-90, such as temperature, moisture, absolute
pressure, water immersion, vibration, shock, and weathering;
(2) the devices are inspected for evidence of
physical damage and for loss of strontium-90 after each stage of testing, using
methods of inspection adequate for determining compliance with the criteria in
subitem (3); and
(3) device designs
are rejected for which the following has been detected for any unit:
(a) a leak resulting in a loss of 0.1 percent
or more of the original amount of strontium-90 from the device;
(b) surface contamination of strontium-90 on
the device of more than 2,200 disintegrations per minute per 100 square
centimeters of surface area; or
(c)
any other evidence of physical damage; and
G. the device has been registered in the
Sealed Source and Device Registry.
Subp. 2. Quality assurance; transfer prohibition.
A. A person licensed under
this part must visually inspect each device and must reject any that has an
observable physical defect that could affect containment of the
strontium-90.
B. A person licensed
under this part must test each device for possible loss of strontium-90 or for
contamination by wiping with filter paper an area of at least 100 square
centimeters on the outside surface of the device or wiping the entire surface
area if it is less than 100 square centimeters. Detection on the filter paper
of more than 2,200 disintegrations per minute of radioactive material per 100
square centimeters of surface wiped must be cause for rejection of the tested
device.
C. A person licensed under
this part must:
(1) maintain quality
assurance systems in the manufacture of the ice detection device containing
strontium-90 in a manner sufficient to provide reasonable assurance that the
safety-related components of the distributed devices are capable of performing
their intended functions; and
(2)
subject inspection lots to acceptance sampling procedures, by procedures
specified in item D and in the license issued under this part, to provide at
least 95 percent confidence that the Lot Tolerance Percent Defective of 5.0
percent will not be exceeded.
D. Each person licensed under this part must
subject each inspection lot to:
(1) tests
that adequately take into account the individual, aggregate, and cumulative
effects of environmental conditions expected in service that could possibly
affect the effective containment of strontium-90, such as absolute pressure and
water immersion; and
(2) inspection
for evidence of physical damage, containment failure, or for loss of
strontium-90 after each stage of testing, using methods of inspection adequate
to determine compliance with the following criteria for defective: a leak
resulting in a loss of 0.1 percent or more of the original amount of
strontium-90 from the device and any other criteria specified in the license
issued under this part.
E. No person licensed
under this part shall transfer to persons generally licensed under part
4731.3240, or under an equivalent general license of the NRC or an agreement
state:
(1) any ice detection device
containing strontium-90 tested and found defective under the criteria specified
in a license issued under this part, unless the defective ice detection device
has been repaired or reworked, retested, and determined by an independent
inspector to meet the applicable acceptance criteria; or
(2) any ice detection device containing
strontium-90 contained within any lot that has been sampled and rejected as a
result of the procedures in item C, subitem (2), unless:
(a) a procedure for defining sub-lot size,
independence, and additional testing procedures is contained in the license
issued under this part; and
(b)
each individual sub-lot is sampled, tested, and accepted in accordance with
unit (a) and item C, subitem (2), and any other criteria as may be required as
a condition of the license issued under this part.
Statutory Authority: MS s 144.1202; 144.1203
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.