Minnesota Administrative Rules
Agency 144 - Health Department
Chapter 4731 - RADIATION SAFETY
IRRADIATORS
Part 4731.6220 - POOL WATER PURITY

Universal Citation: MN Rules 4731.6220

Current through Register Vol. 49, No. 13, September 23, 2024

A. A pool water purification system must be run sufficiently to maintain the conductivity of the pool water below 20 microsiemens per centimeter under normal circumstances. If pool water conductivity rises above 20 microsiemens per centimeter, a licensee must take prompt actions to lower the pool water conductivity and take corrective actions to prevent future recurrences.

B. A licensee must measure the pool water conductivity frequently enough, but no less than weekly, to ensure that the conductivity remains below 20 microsiemens per centimeter. Conductivity meters must be calibrated at least annually.

Statutory Authority: MS s 144.1202; 144.1203

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.