Subpart 1. Required checks.
A licensee must perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:
A.
operability of each aspect of the access control system required under part
4731.6060;
B. functioning of the
source position indicator required under part 4731.6100, item C;
C. operability of the radiation monitor for
radioactive contamination in pool water required under part 4731.6200, subpart
2, using a radiation check source, if applicable;
D. operability of the over-the-pool radiation
monitor at underwater irradiators as required under part 4731.6090, subpart
2;
E. operability of the product
exit monitor required under part 4731.6090, subpart 1;
F. operability of the emergency source return
control required under part 4731.6100, item D;
G. leak-tightness of systems through which
pool water circulates, by visual inspection;
H. operability of the heat and smoke
detectors and extinguisher system required under part 4731.6080, but without
turning extinguishers on;
I.
operability of the means of pool water replenishment required under part
4731.6110, item D;
J. operability
of the indicators of high and low pool water levels required under part
4731.6110, item E;
K. operability
of the intrusion alarm required under part 4731.6060, subpart 2, if
applicable;
L. functioning and wear
of the system, mechanisms, and cables used to raise and lower
sources;
M. condition of the
barrier to prevent products from hitting the sources or source mechanism as
required under part 4731.6120;
N.
amount of water added to the pool to determine if the pool is
leaking;
O. electrical wiring on
required safety systems for radiation damage; and
P. pool water conductivity measurements and
analysis as required under part 4731.6220, item B.
Subp. 2. Repair.
Malfunctions and defects found during inspection and maintenance checks must be repaired without undue delay.
Statutory Authority: MS s 144.1202; 144.1203
Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.