Part 4725.2750 - SCREENS; SCREEN LEADERS, RISERS, AND SUMPS

Universal Citation: MN Rules 4725.2750
Current through Register Vol. 49, No. 13, September 23, 2024

If a screen is attached or connected to the casing, the connection must be made by a threaded, solvent-welded, or welded joint, or by a nontoxic packer. Lead packers must not be used. A screen riser or leader must not extend more than 21 feet above the screen. A screen sump must not extend more than ten feet below the screen. The total combined length of screen riser or leader and screen sump must not exceed 21 feet. A screen riser, leader, or screen sump must comply with the confining layer requirements of part 4725.2020, subpart 1a. Multiple screens separated by a screen riser, leader, or sump are not permitted.

Statutory Authority: MS s 103I.101; 103I.111; 103I.205; 103I.221; 103I.301; 103I.401; 103I.451; 103I.501; 103I.525; 103I.531; 103I.535; 103I.541; 103I.621; 144.05; 144.12; 144.383; 157.04; 157.08; 157.09; 157.13

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.