SEWAGE
Part 4626.1190 - BACKFLOW PREVENTION.* 5-402.11

Universal Citation: MN Rules 4626.1190

Current through Register Vol. 48, No. 39, March 25, 2024

A. Except as specified in items B and, C, and D, a direct connection must not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.P1

B. Item A does not apply to floor drains that originate in refrigerated spaces that are constructed as an integral part of the building.

C. If allowed by chapter 4714, a warewashing machine may have a direct connection between its waste outlet and a floor drain when the machine is located within 5 feet (1.5 meters) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap.

D. If allowed by chapter 4714, a warewashing or culinary sink may have a direct connection.

Statutory Authority: MS s 31.101; 31.11; 144.05; 144.08; 144.12; 157.011

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.