SEWAGE
Part 4626.1190 - BACKFLOW PREVENTION.* 5-402.11
Current through Register Vol. 48, No. 39, March 25, 2024
A. Except as specified in items B and, C, and D, a direct connection must not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.P1
B. Item A does not apply to floor drains that originate in refrigerated spaces that are constructed as an integral part of the building.
C. If allowed by chapter 4714, a warewashing machine may have a direct connection between its waste outlet and a floor drain when the machine is located within 5 feet (1.5 meters) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap.
D. If allowed by chapter 4714, a warewashing or culinary sink may have a direct connection.
Statutory Authority: MS s 31.101; 31.11; 144.05; 144.08; 144.12; 157.011