Part 4626.1470 - LIGHTING INTENSITY. 6-303.11

Universal Citation: MN Rules 4626.1470

Current through Register Vol. 49, No. 13, September 23, 2024

The light intensity must be:

A. at least 10 foot-candles (108 lux) at a distance of 30 inches (75 cm) above the floor, in walk-in refrigeration units and dry food storage areas, and in other areas and rooms during periods of cleaning;

B. at least 20 foot-candles (215 lux):

(1) at a surface where food is provided for consumer self-service, such as buffets and salad bars, or where fresh produce or packaged foods are sold or offered for consumption;

(2) inside equipment such as reach-in and under-counter refrigerators; and

(3) at a distance of 30 inches (75 cm) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and

C. at least 50 foot-candles (540 lux) at a surface where a food employee is working with food or working with utensils or equipment, such as knives, slicers, grinders, or saws where employee safety is a factor.

Statutory Authority: MS s 31.101; 31.11; 144.05; 144.08; 144.12; 157.011

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.