All surfaces of the containment area must be cleaned before abatement. The following actions must be taken before abatement begins.
A. Uncontaminated movable objects must be removed from the containment area.
B. Contaminated objects or objects suspected of being contaminated must be either:
C. Decontaminated movable objects must be removed from the containment area.
D. Objects that cannot be removed from the containment area must be cleaned by HEPA-filter equipped vacuuming or by wet wiping.
E. Before the critical barriers are constructed, all remaining surfaces in the containment area that will be in contact with the critical barriers must be cleaned by HEPA-filter equipped vacuuming or by wet wiping.
F. Any freestanding containment wall that needs to be constructed must be framed after the removal of all movable objects from the containment area.