Part 1545.2920 - LIGHTING

Universal Citation: MN Rules 1545.2920
Current through Register Vol. 48, No. 39, March 25, 2024

There shall be sufficient light consistent with the use to which the particular portion of the building is devoted and to permit efficient cleaning. All rooms in which fish are processed shall be considered as having sufficient light if at least 30 footcandles of light intensity are provided on all working surfaces except that belts and tables on which picking, sorting, or trimming operations are carried on shall be provided with at least 50 footcandles of light intensity. In all other rooms there shall be provided at least five footcandles of light intensity when measured at a distance of 30 inches from the floor.

Statutory Authority: MS s 28A.10

Disclaimer: These regulations may not be the most recent version. Minnesota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.