Minnesota Administrative Rules
Agency 105 - Agriculture Department
Chapter 1513 - ANHYDROUS AMMONIA
SYSTEMS USING DOT PORTABLE TANKS AND CYLINDERS
Part 1513.0920 - CONTAINER AND CYLINDER VALVES AND REGULATION EQUIPMENT
Current through Register Vol. 49, No. 13, September 23, 2024
Subpart 1. Tampering protection.
Container and cylinder valves and pressure regulation equipment must be protected against tampering when installed for use.
Subp. 2. Protection during transit and storage.
Container and cylinder valves shall be protected while in transit, in storage, and while being moved prior to connection to the process line, as follows:
A valve on a cylinder which is enclosed in a box or crate of sufficient strength to protect the valve from damage during transit or storage need not be provided with a protective cap or collar.
Subp. 3. Not in service.
If containers or cylinders are not connected for service, the outlet valves must be kept tightly closed and protected even though containers are considered empty. This requirement does not apply at a facility specifically designed for filling containers or cylinders.
Subp. 4. Cylinder valve connection standards.
Cylinder valves must be in accordance with the connection standard for ammonia as contained in CGA V-1, American National, Canadian, and Compressed Gas Association Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections (ANSI/CSA/CGA V-1).