Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Rehabilitation Code
Section R. 408.30565a - Smoke alarm reference codes
Current through Vol. 24-16, September 15, 2024
Rule 565a. Sections 402.5, 403.10, 804.4.3, and 1104.1 of the code are amended as follows:
402.5. Smoke alarms in existing portions of a building. Where an addition is made to a building or structure of a group R or I-1 occupancy, the existing building shall be provided with smoke alarms in accordance with the Michigan building code.
403.10. Smoke alarms. Individual sleeping units and individual dwelling units in group R and I-1 occupancies shall be provided with smoke alarms in accordance with the Michigan building code.
804.4.3. Smoke alarms. Individual sleeping units and individual dwelling units in any work area in group R and I-1 occupancies shall be provided with smoke alarms in accordance with the Michigan building code.
Exception: Interconnection of smoke alarms outside of the work area shall not be required.
1104.1. Smoke alarms in existing portions of a building. Where an addition is made to a building or structure of a group R or I-1 occupancy, the existing building shall be provided with smoke alarms as required by the Michigan building code or the Michigan residential code as applicable.