Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Elevator Safety Board
Michigan Elevator Rules
Chapter 3 - ASME A17.1 MODIFICATIONS
Section R. 408.7057a - Bottom car clearances
Universal Citation: MI Admin Code R. 408.7057a
Current through Vol. 24-16, September 15, 2024
Rule 57a. Section 2.15.9.2(c) of ASME A17.1 is amended to read as follows:
2.15.9.2(c). Where the installation is the result of replacement or alteration utilizing an existing hoistway and pit, the toe guard may be reduced in length utilizing an existing hoistway and pit, provided the car speed does not exceed 150 feet per minute. The toe guard may be reduced in length proportionate to the maximum length the pit depth will allow complying with section 2.4.1.5. At no time may the toe guard be shorter than the leveling or truck zone plus 75mm, or 3 inches.
Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.