Rule 51. Section 5.4.15.1 of the ASME A17.1 code is amended to read as follows:
5.4.15.1. The inclined elevator shall be operated by weatherproof constant pressure key switches or constant pressure switch or button at each landing and on the car. Key-operated switches shall be of the spring-return type and shall be operated by a cylinder type lock having not less than 5-pin or 5-disk combination with the key removable only when the switch is in the off position. Constant pressure switches and buttons shall be hand operated and controlled by an adjacent on-off key switch with the key removable only when the key is in the off position. The key shall be group 4 security in compliance with section 8.1 of the ASME A17.1 code.