Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Elevator Safety Board
Michigan Elevator Rules
Chapter 3 - ASME A17.1 MODIFICATIONS
Section R. 408.7049 - Buffers
Universal Citation: MI Admin Code R. 408.7049
Current through Vol. 24-16, September 15, 2024
Rule 49. Section 5.4.10.1 of the ASME A17.1 code is amended to read as follows:
5.4.10.1 For rated speeds not exceeding 0.25 m/s (50 ft/min), spring or equivalent type buffers are required. Bumpers or solid stops shall not be permitted.
Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.