Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Elevator Safety Board
Michigan Elevator Rules
Chapter 3 - ASME A17.1 MODIFICATIONS
Section R. 408.7031a - Automated equipment utilizing elevator

Universal Citation: MI Admin Code R. 408.7031a

Current through Vol. 24-16, September 15, 2024

Rule 31a.

(1) Not more than 1 elevator in a bank may be occupied by an automated device at any 1 time. If a single elevator bank is selected due to normal power supply loss, automated devices may not utilize that car. General public passenger cars may not be used to transport automated devices.

(2) A maintenance program for devices must be instituted by the building owner and be available to the requestor upon request.

(3) Devices that utilize multiple carts must be tested annually with all possible variations of carts. Records must be kept onsite and be available to the requestor upon request.

(4) All circuitry and controllers must be kept out of elevator machine rooms and control spaces.

(5) Proper signage must be posted at each elevator connected to the automated devices. Signs must include both of the following language:

(a) Do not enter or use elevator if automated carts are entering, exiting, or on the car.

(b) Service elevator interfaced with automated carts, "Stand clear!"

(6) Any interfacing must comply with R 408.7030.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.