Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Construction Code Commission General Rules
Construction Code
Part 7 - PLUMBING CODE
AMENDMENTS AND ADDITIONS TO BASIC PLUMBING CODE
Section R. 408.30758 - Minimum number of fixtures
Current through Vol. 24-16, September 15, 2024
Rule 758. Sections 403.1, 403.1.1 and 403.3.1 and Table 403.1 of the code are amended to read as follows:
403.1. Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined in accordance with the Michigan building code. Occupancy classification shall be determined in accordance with the Michigan building code.
Exceptions:
Exceptions:
403.3.1. Access. The route to the public toilet facilities required by section 403.3 shall not pass through kitchens, storage rooms, or closets. Access to the required facilities shall be from within the building. All routes shall comply with the accessibility requirements of the Michigan building code. The public shall have access to the required toilet facilities at all times that the building is occupied.
TABLE 403.1
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
(See Sections 403.1.1 and 403.2)
NO. |
CLASSIFICATION |
OCCUPANCY |
DESCRIPTION |
WATER CLOSETS (URINALS SEE SECTION 419.2) |
LAVATORIES |
BATHTUBS/ SHOWERS |
DRINKING FOUNTAIN e,f (SEE SECTION 410.1) |
OTHER |
||
MALE |
FEMALE |
MALE |
FEMALE |
|||||||
1 |
Assembly |
A-1d |
Theaters and other buildings for the performing arts and motion pictures |
1 per 125 |
1 per 65 |
1 per 200 |
1 per 500 |
1 service sink |
||
A-2d |
Nightclubs, bars, taverns, dance halls, and buildings for similar purposes |
1 per 40 |
1 per 40 |
1 per 75 |
1 per 500 |
1 service sink |
||||
Restaurants, banquet halls and food courts |
1 per 75 |
1 per 75 |
1 per 200 |
1 per 500 |
1 service sink |
|||||
Casino gaming areas |
1 per 100 for the first 400 and 1 per 250 for the remainder exceeding 400 |
1 per 50 for the first 400 and 1 per 150 for the remainder exceeding 400 |
1 per 250 for the first 750 and 1 per 500 for the remainder exceeding 750 |
_____ |
1 per 1,000 |
1 service sink |
||||
A-3d |
Auditoriums without permanent seating, art galleries, exhibition halls, museums, lecture halls, libraries, arcades, and gymnasiums |
1 per 125 |
1 per 65 |
1 per 200 |
1 per 500 |
1 service sink |
||||
Passenger terminals and transportation facilities |
1 per 500 |
1 per 500 |
1 per 750 |
1 per 1,000 |
1 service sink |
|||||
Places of worship and other religious services. |
1 per 150 |
1 per 75 |
1 per 200 |
1 per 1,000 |
1 service sink |
|||||
A-4 |
Coliseums, arenas, skating rinks, pools, and tennis courts for indoor sporting events and activities |
1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 |
1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 |
1 per 200 |
1 per 150 |
1 per 1,000 |
1 service sink |
|||
A-5 |
Stadiums, amusement parks, bleachers, and grandstands for outdoor sporting events and activities |
1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 |
1 per 40 for the first 1,520 and 1 per 120 for the remainder exceeding 1,520 |
1 per 200 |
1 per 150 |
1 per 1,000 |
1 service sink |
|||
2 |
Business |
B |
Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial, and similar uses |
1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 |
1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 |
1 per 100 |
1 service sinke |
|||
3 |
Educational |
E |
Educational facilities |
1 per 50 |
1 per 50 |
1 per 100 |
1 service sink |
|||
4 |
Factory and industrial |
F-1 and F-2 |
Structures in which occupants are engaged in work fabricating, assembling, or processing of products or materials |
1 per 100 |
1 per 100 |
1 per 400 |
1 service sink |
|||
5 |
Institutional |
I-1 |
Custodial care facilities |
1 per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
||
I-2 |
Medical care recipients in hospitals and nursing homes |
1 per room c |
1 per room c |
1 per 15 |
1 per 100 |
1 service sink per floor |
||||
Employees in hospitals and nursing homesb |
1 per 25 |
1 per 35 |
1 per 100 |
|||||||
Visitors in hospitals and nursing homes |
1 per 75 |
1 per 100 |
1 per 500 |
|||||||
I-3 |
Prisonsb |
1 per cell |
1 per cell |
1 per 15 |
1 per 100 |
1 service sink |
||||
Reformatories, detention centers, and correctional centersb |
1 per 15 |
1 per 15 |
1 per 15 |
1 per 100 |
1 service sink |
|||||
Employees in reformatories, detention centers and correctional centersb |
1 per 25 |
1 per 35 |
- |
1 per 100 |
- |
|||||
I-4 |
Adult day care and childcare |
1 per 15 |
1 per 15 |
1 |
1 per 100 |
1 service sink |
||||
6 |
Mercantile |
M-1 |
Retail stores, service stations, shops, salesrooms, markets and shopping centers |
1 per 500 |
1 per 750 |
___ |
1 per 1,000 |
1 service sink |
||
R-1 |
Hotels, motels, and boarding houses (transient) |
1 per sleeping unit |
1 per sleeping unit |
1 per sleeping unit |
____ |
1 service sink |
||||
R-2 |
Dormitories, fraternities, sororities and boarding houses (not transient) |
1 per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
||||
7 |
Residential |
R-2 |
Apartment house |
1 per dwelling unit |
1 per dwelling unit |
1 per dwelling unit |
_____ |
1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per 20 dwelling units |
||
R-3 |
Congregate living facilities with 16 or fewer individuals |
1 per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
||||
R-3 |
1 and 2 family dwelling and lodging houses with five or fewer guestrooms |
1 per dwelling unit |
1 per dwelling unit |
1 per dwelling unit |
_____ |
1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per dwelling unit |
||||
R-4 |
Congregate living facilities with 16 or fewer individuals |
1 per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
||||
8 |
Storage |
S-1 S-2 |
Structure for the storage of goods, warehouses, storehouses, and freight depots. Low and moderate hazard. |
1 per 100 |
1 per 100 |
_____ |
1 per 1,000 |
1 service sink |