Michigan Administrative Code
Department - Licensing and Regulatory Affairs
Bureau of Construction Codes
Construction Code Commission General Rules
Construction Code
Part 5 - RESIDENTIAL CODE
Section R. 408.30547c - General
Current through Vol. 24-16, September 15, 2024
Rule 547c.
Sections N1101.3.1, N1101.7, N1101.10, N1101.12.3, N1101.16, tables N1101.10, and N1101.10.2(2) are amended and figure N1101.10a of the code is added to read as follows:
N1101.3.1 (R101.4.3). Additions, alterations, renovations, or repairs. Additions, alterations, renovations, or repairs to an existing building, building system, or portion thereof shall conform to the provisions of this code as they relate to new construction without requiring the unaltered portion(s) of the existing building or building system to comply with this code. Additions, alterations, renovations, or repairs shall not create an unsafe or hazardous condition or overload existing building systems. An addition shall be deemed to comply with this code if the addition alone complies or if the existing building and addition comply with this code as a single building.
Exception: The following are exempt provided the energy use of the building is not increased:
N1101.7 (R102.1.1). Above code programs. The state construction code commission may evaluate and approve a national, state, or local energy efficiency program to exceed the energy efficiency required by this code. Buildings approved in writing by such an energy efficiency program, such as ICC 700-2012 "silver" or energy star version 3 (rev. 07), shall be considered in compliance with this code. The requirements identified as "mandatory" in chapter 4 shall be met.
N1101.10 (R301.1). Climate zones. Climate zones from figures 301.1, 301.1a or table 301.1 shall be used in determining the applicable requirements of this code.
N1101.12.3. Fenestration product rating. U-factors of fenestration products (windows, doors, and skylights) shall be determined in accordance with NFRC 100 by an accredited, independent laboratory, and labeled and certified by the manufacturer. Products lacking such a labeled U-factor shall be assigned a default U-factor from table N1101.12.3(1) or N1101.12.3(2).
Exception: Computer simulations by independent NFRC certified laboratories or approval under section 21 of 1972 PA 230, MCL 125.1521 is considered in compliance with this section.
N1101.16 (R401.3). Certificate (mandatory). A permanent certificate shall be posted on or in the electrical distribution panel, and shall meet all of the following:
Table N1101.10
Climate Zones by County
Zones |
||
5A |
6A |
7 |
Allegan |
Alcona |
Baraga |
Barry |
Alger |
Chippewa |
Bay |
Alpena |
Gogebic |
Berrien |
Antrim |
Houghton |
Branch |
Arenac |
Iron |
Calhoun |
Benzie |
Keweenaw |
Cass |
Charlevoix |
Luce |
Clinton |
Cheboygan |
Mackinac |
Eaton |
Clare |
Ontonagon |
Genesee |
Crawford |
Schoolcraft |
Gratiot |
Delta |
|
Hillsdale |
Dickinson |
|
Ingham |
Emmet |
|
Ionia |
Gladwin |
|
Jackson |
Grand Traverse |
|
Kalamazoo |
Huron |
|
Kent |
Iosco |
|
Lapeer |
Isabella |
|
Lenawee |
Kalkaska |
|
Livingston |
Lake |
|
Macomb |
Leelanau |
|
Midland |
Manistee |
|
Monroe |
Marquette |
|
Montcalm |
Mason |
|
Muskegon |
Mecosta |
|
Oakland |
Menominee |
|
Ottawa |
Missaukee |
|
Saginaw |
Montmorency |
|
Shiawassee |
Newaygo |
|
St. Clair |
Oceana |
|
St. Joseph |
Ogemaw |
|
Tuscola |
Osceola |
|
Van Buren |
Oscoda |
|
Washtenaw |
Otsego |
|
Wayne |
Presque Isle |
|
Roscommon |
||
Sanilac |
||
Wexford |
Key: A Moist. Absence of moisture designation indicates moisture regime is irrelevant.
Table N1101.10.2(2)
Climate Zone Definitions
Zone Number |
Thermal Criteria |
|
IP Units |
SI Units |
|
5A |
5400 [LESS THAN] HDD65°F[LESS THAN EQUAL TO]7200 |
3000 [LESS THAN] HDD18°F[LESS THAN EQUAL TO]4000 |
6A |
7200 [LESS THAN] HDD65°F[LESS THAN EQUAL TO]9000 |
4000 [LESS THAN] HDD18°F[LESS THAN EQUAL TO]5000 |
7 |
9000 [LESS THAN] HDD65°F[LESS THAN EQUAL TO]12600 |
5000 < HDD18°F[LESS THAN EQUAL TO]7000 |
For SI: ºC = [(ºF)-32]/1.8