Section R. 408.30533 - Frost closure
Universal Citation: MI Admin Code R. 408.30533
Current through Vol. 24-16, September 15, 2024
Rule 533. Section P3103.2 of the code is amended to read as follows:
P3103.2. Frost closure. To prevent frost closure, every vent extension through a roof shall be not less than 3 inches (76 mm) in diameter. Any increase in the size of the vent shall be made inside the building with a minimum of 1 foot (305 mm) below the roof or inside the wall.
Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.