Section R. 408.30522a - Vapor retarders

Universal Citation: MI Admin Code R. 408.30522a

Current through Vol. 24-16, September 15, 2024

Rule 522a.

Section R601.3 of the code is amended to read as follows:

R601.3. Vapor retarders. Class I or II vapor retarders shall be provided on the interior side of frame walls in zones 5, 6, 7, 8, and marine 4.

Exceptions:

1. As permitted in table R702.7.1.

2. Class III or no vapor retarder shall be permitted on the interior side of below grade wall assemblies. Class I or II vapor retarders shall be permitted on the interior side of the wall assembly when no air permeable insulation is installed in the below grade wall assemblies.

3. Construction where moisture or its freezing will not damage the materials.

Disclaimer: These regulations may not be the most recent version. Michigan may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.